COMMISSIONING
80 Service Manual Part No.: 4417340 Revision 1
954 SmartServo FlexLine
Name Value Range Default Value Explanation
[Upper reference level] <27.0>
The upper reference level is
used to compute the ullage
level.
The ullage level is defined
as:
Ullage level = Upper
reference level - innage
level..
[Tank top level] <100.0>
The Tank top level is used
during a calibration test to
determine if the calculated
innage is still within
acceptable range.
[Motor limit switch high] <100.0>
The motor limit switch high
level indicates the highest
position the displacer
may reach during normal
operation.
This limit needs to be more
than 10 mm above the low
limit.
[Motor limit switch low] <200.0>
The motor limit switch low
level indicates the lowest
position the displacer
may reach during normal
operation.
[Dip Height] <0.3>
Determines how high the
displacer will stay above the
Interface 1 (Product level)
during dip mode.
[Dip interval time] <60>
Determines the time in
between 2 consecutive
interface 1 dips
[Reference level]
<-100.0> Level used to set the innage
product level.
[Accept reference]
This command sets the
innage product level
indicated by the reference
level.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell FlexLine SmartServo 954 and is the answer not in the manual?

Honeywell FlexLine SmartServo 954 Specifications

General IconGeneral
BrandHoneywell
ModelFlexLine SmartServo 954
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals