143
Chapter 6, Call Processing Subsystem
Using the CALL CONTROL Screen to Test Call Processing Functions
Pwr Lvl: (right-hand field) - Enter the Voice Mobile Attenuation Code (VMAC). The
VMAC determines the mobile station power level to be used on the voice channel (See
Chan: field description, on page 125 for more information about voice channel).
g. DSAT: (right-hand field, NAMPS system type only) - Select the DSAT Color Code
(DSCC) to be used on the voice channel (See Chan: field description, on page
125 for more information about voice channel)
SAT: (right-hand field) - Enter the SAT frequency to be used on the voice channel (See
Chan: field description, on page 125 for more information about the voice channel).
4. Select CALL CNFG from the To Screen menu. The CALL CONFIGURATION
screen will be displayed.
5. Verify that the Test Set’s configuration information is appropriate for the mobile station
to be tested. Check the following fields:
a. CMAX - Set the number of access channels in the system. This will determine how
many channels must be scanned by the mobile station when trying to access the Test
Set. The value of this field will affect the time required for the mobile station to con-
nect with the Test Set.
Turn On The Test Set’s Control Channel
If not already done, condition the Test Set. See "Conditioning the Test Set for Call Pro-
cessing" on page 141 for further information.
1. If not already done, configure the Test Set. See "Configure the Test Set" on page 142
for further information.
2. If the CALL CONTROL screen is not displayed, select CALL CNTL from the To
Screen menu. The CALL CONTROL screen will be displayed.
3. Select the Active field. The Active annunciator will light when the control channel
is turned on.