155
Chapter 6, Call Processing Subsystem
Using the CALL CONTROL Screen to test AMPS Authentication
11. Select SSD Upd in the CC Order field. The Access annunciator light will light while
the SSD Update order is in progress. If the mobile station responds properly on the
reverse control-channel, “SSD Update Order Successful” will be displayed
in the upper right-hand portion of the CALL CONTROL screen. The test set and the
mobile station now share common secret data and further call processing functions with
authentication can be tested. If the order failed, then SSD Update Order
Failed” will appear on the upper right-hand portion of the CALL CONTROL screen.
Initializing Authentication without Registration
1. Ensure that the Test Set is in the active state. See "Turn on the Test Set’s Control
Channel" on page 154 for information on how to activate the Test Set.
2. Connect the mobile station to the Test Set as shown in Figure 17, "Connecting a
Mobile Station to the Test Set," on page 119.
3. Turn on the mobile station.
4. If the CALL CONTROL screen is not displayed, select CALL CNTL from the To
Screen menu. The CALL CONTROL screen will be displayed.
5. Position the cursor on the Display field and select Data.
6. Select the upper MS ID field and then select MIN2 MIN1 from the Choices: menu.
7. Select the lower MS ID field and enter the information in hexadecimal format.
8. Select AUTHEN from the To Screen menu. The AUTHENTICATION screen will be
displayed.
9. Select the A_KEY field and enter a valid A_KEY in decimal format.
10. Select the ESN field and enter the mobile station’s electronic serial number in a
hexadecimal format.
11. Position the cursor on the Off/On field and select On.
12. Select CALL CNTL from the To Screen menu. The CALL CONTROL screen will
be displayed.
13. Select SSD Upd from the CC Order field. The Access annunciator light will light
while the SSD Update order is in progress. If the mobile station responds properly on
the reverse control-channel, “SSD Update Order Successful” will be
displayed in the upper right-hand portion of the CALL CONTROL screen. The test set
and the mobile station now share common secret data and further call processing
functions with authentication can be tested. If the order failed, then “SSD Update
Order Failed” will appear on the upper right-hand portion of the CALL
CONTROL screen.