62
S:\HP892XX\USRGUIDE\manual\opoverv.fb
Chapter 3, Operating Overview
Displaying Measurements
To Use the Analog METER Format
To display measurement results using the analog meter format, use the following
procedure.
1. Position the cursor in front of the unit-of-measure for the measurement you want to dis-
play.
2. Press and release the SHIFT key, then the INCR SET key to display the Meters menu
in the lower-right corner of the screen.
3. Select On/Off to display the meter.
4. Repeat steps 1 and 2 to enter each meter end point and the meter intervals.
5. Repeat steps 1, 2, and 3 to cancel the METER function.
The METER function displays an equivalent analog display. (This is the SINAD
measurement’s default state when the instrument is turned on or preset). As the
measurement is displayed graphically on the meter, the value is also displayed in
small digits below the meter.
You can specify the high and low end points and display interval, or you can use
the default meter settings.
This function is only available for measurements displayed using the large digits,
such as the measurements displayed in the RX TEST and TX TEST screens.
To Make Beat Frequency Measurements
1. Select the DUPLEX TEST screen to set up for beat frequency oscillator measurements.
2. Set the AF Anl In field to SSB Demod.
3. Manually adjust the Tune Freq field to the desired carrier frequency.