387
Chapter 10, Signaling Encoder (AF Generator 2)
EDACS Encoder
Status
This field indicates what the encoder is doing.
Idle is displayed when no data is being sent.
Control is displayed when control channel data is being output.
Working is displayed when a handshake has been performed and working channel data
is being sent.
Sub-Audible Dev
This field is used to specify the low-speed data level. The unit-of-measure used
depends on the
AFGen2 To setting.
•When AFGen2 To is set to FM, the displayed units are kHz or Hz. This is the normal-
ly-used setting for testing EDACS radios.
•When AFGen2 To is set to AM, the displayed unit is %.
•When AFGen2 To is set to Audio Out, the displayed units are µV, mV, or V.
See Also
AFGen2 To
field description, on page 383
Stop
This field is used to stop the control channel or working channel data from being
output. The carrier continues to be output, but without the digital modulation.
Working Channel, Number
This field is used to specify the working channel number for the EDACS system
(typically 1 to 25).
Working Channel: RX Frequency
This field is used to specify the working’s channel receive frequency for the
mobile.
Working Channel: TX Frequency
This field is used to specify the working channel’s transmit frequency for the
mobile.