Chapter 14, Oscilloscope Screen
Field Descriptions
Oscilloscope Main Menu Fields
Figure 111 Oscilloscope Main Functions
Time/div
This field selects the horizontal sweep time per division.
Operating Considerations
The time-per-division is selected from a list of choices.
Vert Offset
Vertical offset moves the displayed signal above or below the oscilloscope’s fixed
centerline.
Operating Considerations
A centerline is displayed for the signal when an offset is used.
When the vertical offset is
0.00, the marker level is referenced to the center line
generated by the vertical offset feature, not the center line of the screen.
Vert/div
Vertical sensitivity sets the vertical amplitude per division.
Operating Considerations
The value for this field is selected from a list of choices.
Depending on the AF Analyzer’s
AF Anl In setting, the units for this field may
be in Volts, kHz, or Percent (AM). For example; if the
AF Anl In field is set to
FM Demod, the amplitude is displayed in kHz/div.
oscscrn3.wmf