246
S:\HP892XX\USRGUIDE\manual\callscrn.fb
Chapter 6, Call Processing Subsystem
ANALOG MEAS Screen
Detector
This field is used to select the type of detector used to measure the amplitude of
the audio signal being measured. Refer to the
Detector field description, on page
105
for descriptions of the detectors available.
Filter 1
This field selects one of several standard or optional audio frequency filters which
can be used to condition the audio signal before being analyzed by the Audio
Frequency Analyzer. Refer to the
Filter 1 and Filter 2 field description, on
page 106
for further information.
Filter 2
This field selects one of several standard or optional audio frequency filters which
can be used to condition the audio signal before being analyzed by the Audio
Frequency Analyzer. Refer to the
Filter 1 and Filter 2 field description, on
page 106
for further information.
FM Deviation
This field displays the measured FM deviation of the carrier being transmitted by
the mobile station. Four dashes (----) indicate that no carrier is present to measure.
TX Freq Error
This field displays the frequency error (error = assigned carrier frequency -
measured carrier frequency) of the carrier being transmitted by the mobile station.
Four dashes (----) indicates that there is no carrier frequency present to measure.
TX Power
This field displays the measured RF power of the carrier being transmitted by the
mobile station. Four dashes (----) indicates that there is no carrier present to
measure.