371
Chapter 10, Signaling Encoder (AF Generator 2)
CDCSS Encoder
Send Mode
This field selects the output format used when Send is selected to output a
sequence.
• Single outputs the entire sequence once.
• Burst outputs the sequence the number of times specified in the Bursts field.
• Cont causes the sequence to be output continuously until Stop is selected.
Standard
This field selects the digitally-coded squelch standard for your radio.
Stop
Selecting this field stops the data stream being output when the Send Mode is set
to
Cont or Burst. After this field is selected, the current repetition of the data
stream is finished, and the turn-off code is output.
TOC Time
Turn-off code time defines the length of time the turn-off code is output.
Operating Considerations
This code is always the last information output before the encoder’s Status
indicator changes from
Sending to Idle whether several bursts or only one data
stream is sent. If no TOC is desired, set this field to
0.0000.