Chapter 10, Signaling Encoder (AF Generator 2)
LTR Encoder
Send Mode
This field selects the output format used when Send is selected to output a
sequence.
Cont is typically used for LTR radio testing.
Single outputs Message 1 or Message 2 once.
Burst outputs the message the number of times specified in the Bursts field.
Cont causes the message to be repeated continuously until Stop is selected.
Step is not used with this encoder mode.
Standard
This field selects the trunked radio standard for your radio.
Stop
Selecting this field stops the message being output when the Send Mode is set to
Cont or Burst. After this field is selected, the current repetition of the message is
finished.