2011-12-07 11:28:52 PST Minor SIB 5 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 4 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 3 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 2 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 1 FPC Link Error
2011-12-07 11:28:52 PST Minor SIB 0 FPC Link Error
2011-12-07 11:15:42 PST Minor No Redundant Power for FPC 0-7
2011-12-07 11:15:42 PST Minor No Redundant Power for Rear Chassis
2011-12-07 11:15:42 PST Minor No Redundant Power for Fan 0-2
2011-12-07 11:15:42 PST Minor PDU 1 PSM 3 Absent
2011-12-07 11:15:42 PST Minor PDU 1 PSM 2 Absent
2011-12-07 11:15:42 PST Minor PDU 1 PSM 1 Absent
2011-12-07 11:15:42 PST Minor PDU 1 PSM 0 Absent
2011-12-07 11:15:42 PST Minor PDU 1 Absent
Chassis Alarm Messages on page 120
Chassis Alarm Messages
Chassis alarm messages Indicate a problem with a chassis component such as the cooling
system or power supplies.
See “Troubleshooting the PTX5000 Cooling System” on page 122.
See “Troubleshooting the PTX5000 Centralized Clock Generators” on page 120.
See “Troubleshooting the PTX5000 Control Boards” on page 135.
See “Troubleshooting the PTX5000 FPCs” on page 136.
See “Troubleshooting the PTX5000 Host Subsystem on page 138 .
See “Troubleshooting the PTX5000 PICs and PIC Cables” on page 147.
See “Troubleshooting the PTX5000 Power System” on page 139.
See “Troubleshooting the PTX5000 Routing Engines” on page 145
See “Troubleshooting the PTX5000 Switch Interface Boards” on page 148.
Related
Documentation
PTX5000 Craft Interface Description on page 26
Troubleshooting the PTX5000 Centralized Clock Generators
Problem The following alarms and LEDs indicate a problem with a CCG:
A red alarm indicates that the CCG has failed or has been removed.
A yellow alarm indicates that the CCG is not online.
The yellow FAIL LED on the CCG faceplate is lit.
The green OK LED on the CCG faceplate is not lit.
In Table 32 on page 121, the text in the column labeled ”LCD Message” appears in the
display of the craft interface. The text in the column labeled “CLI Message” appears in
the output from the show chassis alarms command.