nm
19 10GBASE LR SM OPNEXT,INC TRS5020EN-S201 1310
nm
21 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850
nm
22 10GBASE LR SM FINISAR CORP. FTLX1471D3BNL-J1 1310
nm
23 10GBASE SR MM FINISAR CORP. FTLX8571D3BNL-J1 850
nm
For further description of the output from the command, see the Junos OS System
Basics and Services Command Reference.
Related
Documentation
PTX Series PIC Description on page 36•
• Maintaining the PTX5000 PICs on page 112
• Maintaining the PTX5000 PIC Cables on page 112
• Replacing a PTX5000 PIC on page 178
• Replacing a PTX5000 PIC Cable on page 181
• Replacing a PTX5000 PIC SFP+ Transceiver on page 184
• Replacing a PTX5000 PIC CFP Transceiver on page 187
Troubleshooting the PTX5000 Switch Interface Boards
Problem The following alarms and LEDs indicate a problem with a SIB:
• The yellow FAIL LED on the SIB faceplate is lit.
• The green OK LED on the SIB faceplate is not lit.
• A red alarm indicates that the SIB failed or has been removed.
Solution To troubleshoot the SIBs:
1. Check the LEDs on the faceplate of each SIB.
2. Check the SIB LEDs on the craft interface.
3. Use the CLI to check for alarms. Issue the show chassis alarms command to view the
alarms.
user@host> show chassis environment sib
user@host> show chassis environment sib
SIB 0 status:
State Online
Intake Temperature 37 degrees C / 98 degrees F
Exhaust Temperature 36 degrees C / 96 degrees F
Junction Temperature 41 degrees C / 105 degrees F
Power
1.0 V 1000 mV
1.5 V 1500 mV
1.2 V 1199 mV
3.3 V 3300 mV
Copyright © 2012, Juniper Networks, Inc.148
PTX5000 Packet Transport Switch Hardware Guide