Figure 17: Craft Interface LEDs
1
2
g006127
21 3
4
5
4—1— Fan tray LEDsSIB LEDs
5—2— Power system LEDsHost Subsystem LEDs
3—CCG LEDs
Craft Interface Alarm LEDs on page 29
Craft Interface SIB LEDs on page 30
Craft Interface Host Subsystem LEDs on page 30
CCG LEDs on page 30
Fan Trays LEDs on page 31
Craft Interface Alarm LEDs
Two large alarm LEDs are located on the craft interface. Both LEDs can be lit
simultaneously.
The circular red LED lights to indicate a critical condition that can result in a system
shutdown.
The triangular yellow LED lights to indicate a less severe condition that requires
monitoring or maintenance.
The LCD display on the craft interface reports the cause of the alarm. A condition that
causes an alarm LED to light also activates the corresponding alarm relay contact on
the craft interface.
Table 8 on page 29 describes the alarm LEDs.
Table 8: Alarm LEDs on the PTX5000 Craft Interface
DescriptionStateColorShape
Critical alarm LED—Indicates a critical condition that
can cause the packet transport switch to stop
functioning. Possible causes include component
removal, failure, or overheating.
On steadilyRed
Warning alarm LED—Indicates a serious but nonfatal
error condition, such as a maintenance alert or a
significant increase in component temperature.
On steadilyYellow