28
7 Online 52 5 0 2816 7
28
For further description of the output from the commands, see the Junos OS System
Basics and Services Command Reference.
4. Use the following option to display more detailed information:
user@host> show chassis fpc detail
For more detailed output, add the detail option. The following example also specifies
a slot number (0), which is optional:
user@host> show chassis fpc detail 0
user@host> show chassis fpc detail
Slot 0 information:
State Online
Temperature 34 degrees C / 93 degrees F (PMB)
Temperature 32 degrees C / 89 degrees F (Intake)
Temperature 50 degrees C / 122 degrees F (Exhaust
A)
Temperature 43 degrees C / 109 degrees F (Exhaust
B)
Temperature 48 degrees C / 118 degrees F (TL0)
Temperature 52 degrees C / 125 degrees F (TQ0)
Temperature 56 degrees C / 132 degrees F (TL1)
Temperature 57 degrees C / 134 degrees F (TQ1)
Temperature 54 degrees C / 129 degrees F (TL2)
Temperature 55 degrees C / 131 degrees F (TQ2)
Temperature 58 degrees C / 136 degrees F (TL3)
Temperature 58 degrees C / 136 degrees F (TQ3)
Total CPU DRAM 2816 MB
Total SRAM 0 MB
Total SDRAM 0 MB
Start time 2011-12-07 11:24:48 PST
Uptime 1 hour, 30 minutes, 56 seconds
5. Use the show chassis fabric summary command to check the switch fabric.
user@hostshow chassis fabric summary
FRU State Errors
SIB0 Online None
SIB1 Online None
SIB2 Online None
SIB3 Online None
SIB4 Online None
SIB5 Online None
SIB6 Online None
SIB7 Online None
SIB8 Online None
FPC0 Online None
FPC1 Empty
FPC2 Online None
FPC3 Online None
FPC4 Empty
FPC5 Online None
137Copyright © 2012, Juniper Networks, Inc.
Chapter 14: Troubleshooting Packet Transport Switch Hardware Components