4. Use the show chassis fabric fpcs command to check that the fabric planes are enabled.
FPC #2
PFE #0
SIB0_Fcore0 (plane 0) Plane Enabled, Links OK
SIB0_Fcore1 (plane 1) Plane Enabled, Links OK
SIB1_Fcore0 (plane 2) Plane Enabled, Links OK
SIB1_Fcore1 (plane 3) Plane Enabled, Links OK
SIB2_Fcore0 (plane 4) Plane Enabled, Links OK
SIB2_Fcore1 (plane 5) Plane Enabled, Links OK
SIB3_Fcore0 (plane 6) Plane Enabled, Links OK
SIB3_Fcore1 (plane 7) Plane Enabled, Links OK
SIB4_Fcore0 (plane 8) Plane Enabled, Links OK
SIB4_Fcore1 (plane 9) Plane Enabled, Links OK
SIB5_Fcore0 (plane 10) Plane Enabled, Links OK
SIB5_Fcore1 (plane 11) Plane Enabled, Links OK
SIB6_Fcore0 (plane 12) Plane Enabled, Links OK
SIB6_Fcore1 (plane 13) Plane Enabled, Links OK
SIB7_Fcore0 (plane 14) Plane Enabled, Links OK
SIB7_Fcore1 (plane 15) Plane Enabled, Links OK
SIB8_Fcore0 (plane 16) Plane Enabled, Links OK
SIB8_Fcore1 (plane 17) Plane Enabled, Links OK
5. Use the show chassis fabric topology command to query the state of the links.
user@host> show chassis fabric topology
In-link : FPC# FE# TQ# (TQ-TX sub-chnl #) -->
SIB# TF#_FCORE# (TF-RX port#, TF-RX sub-chn#, TF-RX inst#)
Out-link : SIB# TF#_FCORE# (TF-TX port#, TF-TX sub-chn#, TF-TX inst#)
-->
FPC# FE# TQ# (TQ-RX sub-chnl #)
SIB 6 FCHIP 0 FCORE 1 :
-
In-links State Out-links
State
-
FPC00FE0TQ0(13)-->S06F0_1(3,4,11) Down S06F0_1(7,6,07)-->FPC00FE0TQ0(13)
Down
FPC00FE1TQ1(13)-->S06F0_1(3,5,11) Down S06F0_1(7,4,07)-->FPC00FE1TQ1(13)
Down
FPC00FE2TQ2(13)-->S06F0_1(3,6,11) Down S06F0_1(7,7,07)-->FPC00FE2TQ2(13)
Down
FPC00FE3TQ3(13)-->S06F0_1(3,7,11) Down S06F0_1(7,5,07)-->FPC00FE3TQ3(13)
Down
FPC01FE0TQ0(13)-->S06F0_1(3,0,11) Down S06F0_1(7,2,07)-->FPC01FE0TQ0(13)
Down
FPC01FE1TQ1(13)-->S06F0_1(3,1,11) Down S06F0_1(7,0,07)-->FPC01FE1TQ1(13)
Down
FPC01FE2TQ2(13)-->S06F0_1(3,2,11) Down S06F0_1(7,3,07)-->FPC01FE2TQ2(13)
Down
FPC01FE3TQ3(13)-->S06F0_1(3,3,11) Down S06F0_1(7,1,07)-->FPC01FE3TQ3(13)
Down
FPC02FE0TQ0(13)-->S06F0_1(2,4,10) OK S06F0_1(6,5,06)-->FPC02FE0TQ0(13)
OK
FPC02FE1TQ1(13)-->S06F0_1(2,5,10) OK S06F0_1(6,4,06)-->FPC02FE1TQ1(13)
OK
FPC02FE2TQ2(13)-->S06F0_1(2,6,10) OK S06F0_1(6,7,06)-->FPC02FE2TQ2(13)
OK
FPC02FE3TQ3(13)-->S06F0_1(2,7,10) OK S06F0_1(6,6,06)-->FPC02FE3TQ3(13)
OK
Copyright © 2012, Juniper Networks, Inc.152
PTX5000 Packet Transport Switch Hardware Guide