CAUTION: Avoid bending fiber-optic cable beyond its minimum bend
radius.An arc smaller than a few inches in diametercan damage the cable
and cause problems that are difficult to diagnose.
CAUTION: Do not let fiber-optic cable hang free from the connector. Do
not allow fastened loops of cable to dangle, which stresses the cable at
the fastening point.
5. Insert the other end of the cable into the destination port.
6. Repeat the previous steps for any additional cables.
7. If the PIC is offline (its failure indicator LED is lit), use one of the following methods
to bring the PIC online:
Press the PIC offline/online button until the PIC LED lights green.
Issue the following CLI command:
user@host>request chassis pic fpc-slot fpc-slot pic-slot pic-slot online
For more information about the command, see the Junos OS System Basics and
Services Command Reference.
The normal functioning indicator LED confirms that the PIC is online. You can also
verify correct PIC functioning by issuing the show chassis fpc pic-status command.