Maintenance 10
Keysight N1911A/1912A User’s Guide 273
310
System error;Sensor EEPROM Read Failed - unknown EEPROM table format
This indicates a failure with your E-Series or N8480 Series power sensor. Refer to your power sensor manual
for details on returning it for repair.
310
System error;Sensor EEPROM < > data not found or unreadable
Where < > refers to the sensor data block covered, for example, Linearity, Temp - Comp (temperature
compensation).
This indicates a failure with your E-Series or N8480 Series power sensor. Refer to your power sensor manual
for details on returning it for repair.
310
System error;Sensors connected to both front and rear inputs.
You cannot connect two power sensors to the one channel input. In this instance the power meter detects
power sensors connected to both it’s front and rear channel inputs.
321
Out of memory
The power meter required more memory than was available to run an internal operation.
330
Self-test Failed;
The -330, “Self-test Failed” errors indicate that you have a problem with your power meter. Refer to
“Contacting Keysight Technologies” on page 277 for details of what to do with your faulty power meter.
330
Self-test Failed;Measurement Channel Fault
330
Self-test Failed;Measurement Channel A Fault
330
Self-test Failed;Measurement Channel B Fault
330
Self-test Failed;Calibrator Fault
Refer to “Calibrator” on page 264 if you require a description of the calibrator test.
330
Self-test Failed;ROM Check Failed
330
Self-test Failed;RAM Check Failed
330
Self-test Failed;Display Assy. Fault
Refer to “Display” on page 265 if you require a description of the Display test.
350
Queue overflow
The error queue is full and another error has occurred which could not be recorded.
361
Parity error in program
The serial port receiver has detected a parity error and consequently, data integrity cannot be guaranteed.
362
Framing error in program
The serial port receiver has detected a framing error and consequently, data integrity cannot be guaranteed.