Repair information 4-119
5026
5. Grasp the handles (B), slide the fuser out from the printer.
Installation note: If you install a new fuser, be sure to reset the fuser counter in the Configuration Menu, and
run the Motor Calibration. To reset the counter and run the calibration:
1. Enter the Configuration Menu. (Turn off the printer, press and hold buttons 2 and 6, turn on the printer, and
release the buttons when the progress bar displays.)
2. Press for the Reset value.
Resetting Fuser Count Value appears.
3. Select Motor Calibration from the CONFIG MENU.
Calibrating displays, and the printer prints several blank pages and then returns to the CONFIG MENU.
4. Select Exit Config Menu.