Repair information 4-211
5026
Go Back
Previous
Next
HCIT slide assembly with spring removal
1. Remove the HCIT controller board assembly. See “HCIT controller board assembly removal” on
page 4-207.
2. Disconnect the two springs (A) from the frame.
Note: Leave the springs attached to the cam size sensing plate (B) and the actuator switch.
3. Slide the cam size sensing plate (B) through the access hole in the rear side frame.
4. Remove the media size actuator from the card mount option (C).
5. Snap loose the actuator switch (D), and remove.