7-70 Service Manual
7562
40X7171 10J0974 Weather
station
compensation
thermistor
On LVPS
•System board connector:
JCCT2
See step 5 of“Low-voltage power
supply (LVPS) removal” on
page 4-81.
10J1370 Fuser thermal
guide
assembly
Behind fuser See “Fuser thermistor removal”
on page 4-66.
40X7189 10J4303 Cave
light/Output
bin cable
Connects to bin-full sensor and
to cave light cable under
scanner left side front cover
•System board connector:
JTCVR1
1. Disconnect the cable from the bin
full sensor. See “Bin-full sensor
removal” on page 4-34.
2. Disconnect the cable from under
the scanner left side covers. See
“Scanner left side front cover
removal” on page 4-214 and
“Scanner left side rear cover
removal” on page 4-214.
40X7199 10J0963 Front host
USB cable
OP panel housing to UICC
card
“Front USB cable removal” on
page 4-59
10J0971 Panel USB
Hub - H cable
Under flatbed scanner
assembly
•System board connector:
JFMUSB
“OP panel cables removal” on
page 4-110
10J4302 AIO cavelight
cable
Connects to the OP panel
housing and to cable 10J4303
under the scanner left side
covers.
10J4308 24-pin UICC
cable
Under flatbed scanner
assembly
• System board connector: J1
17X0054 30-pin UICC
LCD cable
OP panel UICC card to display
40X7199 ADF beacon
LED cable
On the bottom of the ADF
document tray
“ADF beacon cable removal” on
page 4-173
Cable location table
P/N item number Description Location To access