Issue 5 November 2000 
363-206-208
Equipment and Front Access Cable Installation for the DDM-2000 OC-12 Multiplexer
Lucent Technologies - Proprietary
See Notice on first page
Table 3-2 ED8C900-20 DS3 Cable Assemblies
Application
(Note 1)
Length Per
Table 2-2*
Column
Factory
Term.
Groupsâ€
Cable Type
(Note 2)
Connectors
Types
Cables
Per
Muldm
Cables
per
Shelf
DSX-3 or FT-2000 1A AB, LA 735A Straight
BNC to
Right Angle
BNC
624
OC-48 2A 6BB, 6LA 1735006A 1 6
4A DBD, 1LA 735A-734D 6 24
4A DB, 1LA 734D 6 24
DACS III-2000
With BNC
Interconnect Shelf
1A AB, LA 735A Straight
BNC to
Right Angle
BNC
624
2A 6BB, 6LA 1735006A 1 6
4A DBD, 1LA 735A-734D 6 24
4A DB, 1LB 734D 9821AE to
Right Angle
BNC
624
Without BNC
Interconnect Shelf
1A AC, LB 735A 6 24
2A 6BC, 6LB 1735006A 1 6
4A DBD, LCD 735A-734D-
735A
624
DACS IV-2000
With BNC
Interconnect Shelf
1A AB, LA 735A Straight
BNC to
Right Angle
BNC
624
2A 6BB, 6LA 1735006A 1 6
4A DBD, 1LA 735A-734D 6 24
4A DB, 1LA 734D 6 24
Without BNC
Interconnect Shelf
1A AE, LB 735A 9821FA/
9821AE to
Right Angle
BNC
312
AD, LB 3 12
2A 6BJ, 6LB 1735006A 1 6
4A DBD, LED 735A-734D-
735A
9821AE to
Right Angle
BNC
312
DBD, LDD 3 12
Table 3-2 Notes:
1. All the DS3 cable assemblies can be used for any muldem. The OC-12 DS3 backplane connectors are
J30-J35 (for muldem A), J36-J41 (for muldem B), J42-J47 (for muldem C), and J48-J53 (for muldem D).
* 1A, 2A and 4A refer to Table 2-3 columns on Pages 2-35 and 2-36 providing the cable lenghts and asso-
ciated Cable Group numbers. This information is also shown on ED8C900-20.
†This column lists the ED8C900-20 Groups for factory terminations at each end of the cable.