 Issue 5 November 2000
363-206-208
Stand-Alone (Local) Installation Tests for the DDM-2000 OC-12 Multiplexer
Lucent Technologies - Proprietary
See Notice on first page
NOTE:
Release a.b.c is the software release.
(6) Once logged in, the user can only issue commands to the on-line shelf. To com-
municate with another shelf in the bay, through the other shelf’s CIT, the user
will first have to terminate the session with the current shelf. The session is ter-
minated with the
log; (LOGOUT) command.
NOTE:
To communicate with another shelf it is possible to log in remotely while still
logged in to the local shelf. It is not possible to remotely log in to another shelf
without being logged in to the local shelf through its CIT.
(7) Issue the command
init-sys:all; (INITIALIZE SYSTEM). This command
will configure the DDM-2000 OC-12 with its default parameters.
(8) When initialization completes, repeat steps 2 through 5 to log back into the
shelf.
(9) For Releases 5, an AGNE alarm will exist upon completion of the initialization.
To extinguish this alarm, set the AGNE to yes by using the
set-ne (SET NET-
WORK ELEMENT) command.
(10)To change the target identifier (TID), which is the name of the shelf, issue the
command
set-ne (SET NETWORK ELEMENT). When prompted with TID=
enter the desired TID consisting of up to 20 alphanumeric characters. For
Releases prior to 5, at the GNE= prompt enter no at this time.
(11)To change the number of lines displayed at a time (default = 24), issue the com-
mand
set-link (SET LINK). Respond to the page length prompt (pg) with
the desired number of lines, between
3 and 150.
(12)To change the time delay for alarms to be displayed or cleared, issue the com-
mand set-attr-alm (SET ATTRIBUTE ALARM). To eliminate any alarm
delay, i.e., to clear delay, respond to the prompts with
0.
(13)To change the time and date displayed, issue the command
set-date (SET
DATE). Respond to the date and time prompts.