System Memory
System Memory
The CPU configuration supports 256MB on-board flash. The system optimizes for the amount of RAM available.
Internal flash is used for boot loader code and system low-level diagnostics code. Bootloader code is validated at system
startup.
Internal SD Memory Card
The MX7 Tecton has one SD Memory card slot for Expansion Memory, located in the main battery well, and protected by a
rubber flap. 1GB and 4GB flash memory cards are available from LXE.
Video Subsystem
The touchscreen is a 3.5” (8.9 cm) diagonal viewing area, ¼ VGA 320 by 240 pixel TFT Reflective Active Color LCD.
Backlighting is available and can be turned on and off with key sequences. The turn-off timing is configured through the Start |
Settings | System | Backlight icon. The display controller supports Microsoft CE 6.5 graphics modes.
A touchscreen allows mouse functions (tapping on the display or signature capture) using an LXE approved stylus. The
touchscreen has an actuation force with finger less than 100 grams. The color display has an LED backlight and is optimized
for indoor use.
The display appears black when the MX7 Tecton is in Suspend Mode.
Power Supply
The MX7 Tecton uses one of two batteries for operation.
l Main Battery A replaceable 2200 mAh Lithium-Ion (Li-Ion) battery pack. The battery pack recharges while in the MX7
Tecton when the device is connected to the optional external MX7 Tecton AC/DC power source. The main battery pack
can be removed from the MX7 Tecton and inserted in the MX7T Multi- Charger which simultaneously charges up to five
battery packs in four hours. The MX7 Tecton status indicator is illuminated when the Super-cap battery is being charged
by the main battery pack. A new main battery pack can be fully charged in 6 hours when it is in an MX7 Tecton con-
nected to AC power and 3.5 hours when it is in the MX7T multicharger.
l Low temperature Lithium-Ion (Li-Ion) batteries have a 1250 mAh capacity.
l Super-capacitor (Super-cap). No "backup battery" is used. Super-cap internal battery maintains RAM and other vital
settings during a critical shutdown.
Note: An uninterrupted external power source (wall AC adapters) transfers power to the MX7 Tecton’s internal charging
circuitry which, in turn, recharges the main battery and Super-cap battery. Frequent connection to an external power
source, if feasible, is recommended to maintain main battery charge status as the Super-cap battery cannot be recharged
by a dead or missing main battery.