Operating elements for crane operation
9.2 Short description of the operating elements
9 - 144 Operating manual
GMK5150L
RCL override –
version B
This point only applies to RCL programming deviating from EN 13000.
For RCL programming in accordance with EN 13000;
à p. 9 - 143.
Overriding the RCL in an emergency
No function
No function
1 Press once:
RCL shutdown overridden – crane functions enabled
Crane functions can be started within the next
10 seconds.
Speed of movements increasing load moment
max. 15%.
à RCL override – version B, p. 11 - 67