EasyManua.ls Logo

MASSO G2 - G93 - Inverse Time Mode

MASSO G2
477 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MASSO
MASSO Documentation
8.27. G93 – Inverse Time Mode
This command is used set the current feed rate mode to Inverse Time Mode.
Syntax & Parameters
G93
X, Y, Z, A & B These are the destination coordinates of the axis.
F Value This is the Feedrate. The move will be completed it 1/F minutes or 60/F seconds.
G01, G02 and G03 It is Mandatory to include a Feedrate for these commands
G00 No Feedrate is required
Example program
N10 G93 N20 G01 X1 A1 F30 #This will move TO position X1 A1 in 2 seconds
N30 G00 X0 A0 #This will Rapid to X0 A0
The above program sets the feedrate mode to Inverse Time Mode.
v5.18 - 08 Apr,2021
www.masso.com.au Page 225 of 477

Table of Contents

Related product manuals