9.19. M65 – Turn Off Digital Output Immediately
This command is used to switched OFF any of the 16 auxiliary outputs. If this command is used between
motion commands then the motion will come to full stop before switching OFF the output.
Syntax & Parameters
M65
P Value - The P value is required and defines the output number to switch On. This value can be
between 1 to 16.
Example program
N10 M65 P1 N20 M65 P4
The N10 line will switch OFF the auxiliary output 1.
The N20 line will switch OFF the auxiliary output 4.
INFORMATION: For M65 P# to work you must assign an output as an auxiliary output in F1-Setup
screen under OUTPUTS list.