17. Plasma - Torch Height Control
MASSO supports simple control signals for torch heigh control so that external THC's can be easily
integraded with MASSO.
Input signals used for THC:
THC Input - 1 - is used to tell MASSO to move the Z axis up. When this input goies HIGH, MASSO
will start moving the Z axis up.
THC Input - 2 - is used to tell MASSO to move the Z axis down. When this input goies HIGH,
MASSO will start moving the Z axis down.
Plasma Arc OK Signal - This signal is required to tell MASSO that the arc has been successful. This
signal should go HIGH by the THC on successful arc start.