8.32. G98 – Canned Cycle – Retract Back To The Initial Z
This command is used in combination with canned cycles to retract Z axis to the position before canned
cycles was started.
Syntax & Parameters
G98
Example program
N10 G98 G73 X10 Y10 Z-8 R2 Q1 F100
In the above program, after finishing the drilling cycle the Z axis will retract back to the position before
the drilling cycle.