11.10. Backlash Compensation
When to use backlash compensation
Axis backlash should first be adjust mechanically as its best to first find the source of backlash and if needed
replacing parts. As with any mechanical system there will always be some minor backlash and only very
small backlash should be managed by MASSO's backlash compensation feature.
Information: Maximum backlash value is 10mm or 0.3937", If the value exceeds this, the backlash
value setting will reset.
Enter the measured axis backlash value in the Backlash box. If not using set this value to 0.00