2.10 Controller
2 - 39
2
GOT BASIC SETTING
■2. Channel-Driver assign operation
The following describes how to operate the Channel-Driver assign.
The following description uses an example of changing the serial communication connection to the direct CPU
connection by changing the communication driver from [AJ71QC24, MELDAS C6*] to [Serial(MELSEC)].
POINT
POINT
POINT
Before the operation
The GOT automatically restarts after executing this setting.
If project data has been downloaded, the GOT starts monitoring of the controller after restarting.
Execute this setting after carefully confirming the safety.
Step 1. IInstall the communication driver
[Serial(MELSEC)] to the GOT.
(Download of [Controller Setting] from
GT Designer3 is not required.)
After installing communication driver,
touch the [Channel Driver assign] button
in [Channel-Driver Assign].
Step 2. Touch the [Change assignment] button
on the displayed screen as shown left.
Step 3. As the communication driver
([Serial(MELSEC)]) installed in the GOT
is displayed, touch it.
(Continued to next page)

Table of Contents

Other manuals for Mitsubishi GOT2000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi GOT2000 Series and is the answer not in the manual?

Mitsubishi GOT2000 Series Specifications

General IconGeneral
Power Supply24VDC
SoftwareGT Works3
ProcessorRISC CPU
InterfaceEthernet, USB, RS-232, RS-422/485
Operating Temperature0°C to 50°C
Display TypeTFT LCD
Storage Temperature-20°C to 60°C
Humidity10% to 90% (non-condensing)
Shock Resistance147 m/s² (15G), 11ms duration
Touch PanelAnalog Resistive

Related product manuals