15 TYPE CONVERSION FUNCTIONS
15.34 Converting BCD to DINT
A value input to (s) is within the range from 0H to 9999H (from 0 to 9 for each digit) for the WORD type data value and from
0H to 99999999H (from 0 to 9 for each digit) for the DWORD type data value.
WORD or DWORD can be specified to (s). BOOL cannot be specified.
Operation result
1. Function without EN/ENO
The following table lists the operation results.
2. Function with EN/ENO
The following table lists the execution conditions and operation results.
*1 When FALSE is output from ENO, data output from (d) is undefined. In that case, modify a program so that the data output from (d) is
not used.
Operation error
When (s) is WORD
When (s) is DWORD
Operation result (d)
No operation error occurred Operation output value
An operation error occurred Indefinite value
Execution condition Operation result
EN ENO (d)
TRUE (Executes operation) TRUE (Operation error did not occur) Operation output value
FALSE (Operation error occurred)
*1
Indefinite value
FALSE (Stops operation) FALSE
*1
Indefinite value
Error code
(SD0/SD8067)
Description
3401 A value other than 0 to 9 exists in each digit of (s).
Error code
(SD0/SD8067)
Description
3401 A value other than 0 to 9 exists in each digit of (s).