5 - 15
5 EtherCAT Communications
AC Servomotors/Servo Drives 1S-series with Built-in EtherCAT® Communications User’s Manual (I586)
5-7 Emergency Messages
5
5-7 Emergency Messages
When an error or warning occurs in a 1S-series Servo Drive, an emergency message is sent to the
master through SDO communications. An emergency message is not sent for a communications error.
You can select whether or not to send emergency messages in Diagnosis History (10F3 hex).
When the power supply is turned ON, Diagnosis History – Flags (10F3-05 hex) is set to 0 (not
notify).
To send emergency messages, set the least significant bit of Diagnosis History – Flags (10F3-05 hex)
to 1 every time the power is turned ON.
An emergency message consists of 8-byte data.
Note For details on errors and warnings of the Servo Drive, refer to Section 12 Troubleshooting.
Byte 0 1 2 3 4 5 6 7
Con-
tents
Emergency Error Code
*1
*1. Error codes (FF00 to FFFF hex) in the manufacturer-specific area are used. Byte 0 is fixed to FF hex, and
byte 1 shows the main code of an error number or warning number.
Error Register
(object 1001
hex)
Manufacturer-specific Error Field
*2
*2. Byte 3 is not used. An error code is shown in bytes 4 to 7. For details on error event codes, refer to A-4 Sys-
mac Error Status Codes on page A-100.

Table of Contents

Other manuals for Omron R88D-1SN ECT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron R88D-1SN ECT Series and is the answer not in the manual?

Omron R88D-1SN ECT Series Specifications

General IconGeneral
FeedbackIncremental encoder, Absolute encoder
Position ControlYes
Speed ControlYes
Torque ControlYes
Communication InterfaceEtherCAT
Power Supply Voltage200 to 240 VAC
Output Power0.1 to 1.5 kW
Input Voltage Range170 to 264 VAC
Control MethodSine-wave PWM control
Main Circuit Power Supply200-240 VAC
Applicable Motor Capacity0.1 to 1.5 kW
Protection FunctionsOvercurrent, Overvoltage, Undervoltage, Overheating, Encoder Error
Ambient Operating Temperature0 to 55°C
Vibration Resistance4.9 m/s² (10 to 55 Hz)
Shock Resistance98 m/s2
WeightVaries by model