Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1125User Manual 1178.8520.02 ─ 01
SYSTem:ERRor:DISPlay <State>
This command the error display during remote operation on and off.
If activated, the R&S FSV/A displays a message box at the bottom of the screen that
contains the most recent type of error and the command that caused the error.
Parameters:
<State> ON | OFF | 1 | 0
*RST: 0
Example:
SYST:ERR:DISP ON
Manual operation: See "Display Remote Errors" on page 701
SYSTem:IDENtify:FACTory
This command resets the query to *IDN? to its default value.
Manual operation:
See "Reset to Factory String" on page 700
SYSTem:IDENtify[:STRing] <String>
This command defines the response to *IDN?.
Parameters:
<String> String containing the description of the instrument.
Manual operation: See "Identification String" on page 700
SYSTem:KLOCk <State>
This command activates the local lockout (remote control) or returns to the local mode.
Parameters:
<State> ON
LLO (local lockout)
OFF
GTL (go to local)
*RST: OFF
Example:
SYST:KLOK ON
Activates LLO (remote control)
Manual operation: See "Local" on page 709
SYSTem:LXI:INFO?
This command queries the LXI settings.
Return values:
<LXIInfo> <current version> | <LXI class> | <Computername> |
<MAC adress> | <IP adress> | <Auto MDIX>
String containing the current LXI parameters.
Configuring the R&S FSV/A