Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
745User Manual 1178.8520.02 ─ 01
Measuring Spurious Emissions.............................................................................826
Analyzing Statistics (APD, CCDF)........................................................................ 838
Measuring the Time Domain Power......................................................................848
Measuring the Harmonic Distortion.......................................................................858
Measuring the Third Order Intercept Point............................................................861
Measuring the AM Modulation Depth....................................................................864
List Evaluations.....................................................................................................866
Measuring the Pulse Power.................................................................................. 870
14.5.1 Performing Measurements
Useful commands for performing measurements described elsewhere
INITiate<n>:ESPectrum on page 793
INITiate<n>:SPURious on page 826
Remote commands exclusive for performing measurements:
ABORt.......................................................................................................................... 745
INITiate<n>:CONMeas................................................................................................... 746
INITiate<n>:CONTinuous................................................................................................746
INITiate<n>[:IMMediate]..................................................................................................747
[SENSe:]SWEep:COUNt:CURRent?................................................................................748
ABORt
This command aborts the measurement in the current channel and resets the trigger
system.
To prevent overlapping execution of the subsequent command before the measure-
ment has been aborted successfully, use the *OPC? or *WAI command after ABOR and
before the next command.
For details see Chapter 13.1.6.1, "Preventing Overlapping Execution", on page 664.
Note on blocked remote control programs:
If a sequential command cannot be completed, for example because a triggered sweep
never receives a trigger, the remote control program will never finish and the remote
channel to the R&S FSV/A is blocked for further commands. In this case, you must
interrupt processing on the remote channel first in order to abort the measurement.
To do so, send a "Device Clear" command from the control instrument to the
R&S FSV/A on a parallel channel to clear all currently active remote channels.
Depending on the used interface and protocol, send the following commands:
Visa: viClear()
Now you can send the ABORt command on the remote channel performing the mea-
surement.
Configuring and Performing Measurements