Measurements and Results
R&S
®
FSVA3000/ R&S
®
FSV3000
231User Manual 1178.8520.02 ─ 01
Remote command:
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>[:EXCLusive]
on page 812
To define all limits in one step:
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:LIMit[:STATe]
on page 813
PMin / PMax
Defines the power limits for each power class. The first range always starts at -200
dBm (-INF) and the last range always stops at 200 dBm (+INF). These fields cannot be
modified. If more than one power class is defined, the value of "PMin" must be equal to
the value of "PMax" of the previous power class and vice versa.
Note that the power level can be equal to the lower limit(s), but must be lower than the
upper limit(s):
P
min
≦P<P
max
Otherwise the ranges are corrected automatically.
Remote command:
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MINimum
on page 814
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:MAXimum
on page 814
Sweep List
Switches to the "Sweep List" tab of the "Spectrum Emission Mask" dialog box and
focuses the "Limit Check" setting for the corresponding power class (1-4) in the refer-
ence range (see " Limit Check <n> " on page 225).
Adding or Removing a Power Class
Adds a new power class at the end of the list or removes the last power class. After
adding or removing, the last power class is adapted to end at "+INF" . Note that a max-
imum of four power classes are available.
Remote command:
CALCulate<n>:LIMit<li>:ESPectrum<sb>:PCLass<pc>:COUNt on page 812
7.6.5.5 MSR Settings
Access: "Overview" > "Select Measurement" > "Spectrum Emission Mask" > "MSR
Settings"
Multi-standard radio (MSR) measurements allow you to perform SEM tests on multiple
carriers using different digital standards.
For details, see Chapter 7.6.4.4, "Multi-Standard Radio (MSR) SEM Measurements",
on page 216.
Spectrum Emission Mask (SEM) Measurement