Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
885User Manual 1178.8520.02 ─ 01
14.7 Setting Basic Measurement Parameters
All commands that set measurement-independent parameters are described here.
● Defining the Frequency and Span.........................................................................885
● Configuring Bandwidth and Sweep Settings.........................................................891
● Configuring the Vertical Axis (Amplitude, Scaling)................................................898
● Configuring Triggered and Gated Measurements.................................................908
● Adjusting Settings Automatically...........................................................................919
● Configuring the Data Input and Output................................................................. 921
14.7.1 Defining the Frequency and Span
The commands required to configure the frequency and span settings in a remote envi-
ronment are described here. The tasks for manual operation are described in Chap-
ter 8.3, "Frequency and Span Configuration", on page 358.
● Defining the Frequency Range............................................................................. 885
● Configuring Signal Tracking.................................................................................. 889
14.7.1.1 Defining the Frequency Range
The following commands are required to define the frequency range.
CALCulate<n>:MARKer<m>:FUNCtion:CENTer................................................................ 885
CALCulate<n>:MARKer<m>:FUNCtion:CSTep..................................................................886
DISPlay[:WINDow<n>][:SUBWindow<w>]:TRACe<t>:X:SPACing....................................... 886
[SENSe:]FREQuency:CENTer......................................................................................... 886
[SENSe:]FREQuency:CENTer:STEP................................................................................887
[SENSe:]FREQuency:CENTer:STEP:AUTO......................................................................887
[SENSe:]FREQuency:CENTer:STEP:LINK........................................................................887
[SENSe:]FREQuency:CENTer:STEP:LINK:FACTor............................................................888
[SENSe:]FREQuency:OFFSet.........................................................................................888
[SENSe:]FREQuency:SPAN............................................................................................888
[SENSe:]FREQuency:SPAN:FULL...................................................................................889
[SENSe:]FREQuency:STARt........................................................................................... 889
[SENSe:]FREQuency:STOP............................................................................................889
CALCulate<n>:MARKer<m>:FUNCtion:CENTer
This command matches the center frequency to the frequency of a marker.
If you use the command in combination with a delta marker, that delta marker is turned
into a normal marker.
Suffix:
<n>
.
Window
<m> Marker
Example:
CALC:MARK2:FUNC:CENT
Sets the center frequency to the frequency of marker 2.
Setting Basic Measurement Parameters