Remote Commands
R&S
®
FSVA3000/ R&S
®
FSV3000
1129User Manual 1178.8520.02 ─ 01
Return values:
<Cycles> Number of switching cycles.
Example:
DIAG:INFO:CCO? CAL
Usage: Query only
Manual operation: See " Relays Cycle Counter " on page 632
DEVice:INFO:HWBand?
Queries the frequency bands used for measurement by the R&S FSV/A hardware. The
start frequency of each band is provided.
The bands are instrument-specific and depend on the currently defined RBW, VBW
and YIG preselector state. The precise frequency bands are required to define correc-
tion data for the correct bands, in particular for frequency-drifting DUTs.
This query is only available in zero span mode.
Return values:
<StartFreq>
Example:
//Set to zero span mode
FREQ:SPAN 0
//Set RBW
BAND:RES 1000000
//Set VBW
BAND:VID 10000
//Activate YIG filter
INP:FILT:YIG ON
//Query used hardware bands
DEV:INFO:HWB?
//Result:
//0,50000000,450000000,1000000000,3000000000,4000000000,5200000000,...
The used bands for this instrument and measurement setup are:
0 Hz to 49999999 Hz
50000000 Hz to 44999999
450000000 Hz to 999999999
1000000000 Hz to 2999999999
3000000000 Hz to 3999999999
4000000000 Hz to 5199999999
5200000000 Hz to ...
Usage:
Query only
DIAGnostic:SERVice:BIOSinfo?
This command queries the BIOS version of the CPU board.
Return values:
<BiosInformation> String containing the BIOS version.
Configuring the R&S FSV/A