Network and Remote Operation
R&S
®
FSVA3000/ R&S
®
FSV3000
691User Manual 1178.8520.02 ─ 01
"MATLAB
(Instrument
Control Tool-
box)"
A programming environment, frequently used in signal processing
and test and measurement applications (*.m)
You can use this format directly with the MATLAB© Instrument Con-
trol Toolbox.
"MATLAB
(R&S Toolkit)"
You can use this format directly with the MATLAB© Toolkit.
"NICVI"
An ANSI C programming environment designed for measurements
and tests (*.cvi)
You can use this format directly with National Instruments LabWind-
ows CVI.
"Python"
A commonly used general programming language for various applica-
tions (.py)
Settings
Some additional settings are available to configure the exported SCPI command files.
Add Synchronization Commands ← Settings
If enabled, additional commands are included in the script to synchronize the recorded
commands when necessary. For instance, when a measurement is started, a *WAI
command is inserted to ensure that the next command is only executed after the mea-
surement has finished.
Combined Recording of Spectrum Analyzer and R&S Signal Generator ← Set-
tings
Records commands both from the R&S FSV/A and from a connected R&S signal gen-
erator.
To record commands that are executed by the signal generator, the instruments must
be connected via LAN.
To avoid duplicate commands for the same setting on the individual instruments, you
can couple the most important parameters between the analyzer and the generator
automatically. See Chapter 12.10.3, "Generator Coupling", on page 637.
IP Address or Computer name of Signal Generator ← Settings
The IP address or computer name of the signal generator connected to the
R&S FSV/A via LAN.
For tips on how to determine the default computer name, see Chapter 5.1.5.3, "Using
Computer Names", on page 40, or the signal generator's user documentation.
Automating Tasks with Remote Command Scripts

Table of Contents

Other manuals for R&S FSV3000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the R&S FSV3000 Series and is the answer not in the manual?

R&S FSV3000 Series Specifications

General IconGeneral
TOI (Third-Order Intercept)> +15 dBm
Resolution Bandwidth1 Hz to 1 MHz
Display12.1-inch touchscreen
Analysis Bandwidth40 MHz
Video Bandwidth (VBW)1 Hz to 1 MHz
Amplitude accuracy±0.5 dB
InterfaceUSB
Dynamic Range> 100 dB

Related product manuals