Remote Control Commands
R&S
®
SMB100A
414Operating Manual 1407.0806.32 ─ 21
Options: R&S SMB-B5
Manual operation: See "Pilot Phase - Stereo Modulation" on page 215
[:SOURce]:STEReo:PILot:STATe <State>
Activates/deactivates the pilot tone generation.
Parameters:
<State> 0 | 1 | OFF | ON
*RST: OFF
Example:
STER:PIL:STAT ON
activates generation of the pilot tone.
Options: R&S SMB-B5
Manual operation: See "Pilot State - Stereo Modulation" on page 215
[:SOURce]:STEReo:PILot[:DEViation] <Deviation>
Sets the deviation of the pilot tone.
Parameters:
<Deviation> integer
Range: 0 to 10 kHz
*RST: 6.75 kHz
Example:
SOUR:STER:PIL:DEV 6.75kHz
sets the pilot tone deviation according to standard.
Options: R&S SMB-B5
Manual operation: See "Pilot Deviation - Stereo Modulation" on page 215
[:SOURce]:STEReo:RDS:DATaset <Dataset>
Selects one of the five data sets provided on the instrument for use in the RDS signal.
Parameters:
<Dataset> DS1 | DS2 | DS3 | DS4 | DS5
*RST: DS1
Example:
STER:RDS:DAT DS5
activates use of data set 5 for generation of the RDS signal.
Options: R&S SMB-B5
Manual operation: See "RDS Data Set - Stereo Modulation" on page 217
[:SOURce]:STEReo:RDS:STATe <State>
Activates/deactivates the RDS signal generation. RDS signals can be generated simul-
taneously with MPX and ARI signals.
SOURce Subsystem