Remote Control Commands
R&S
®
SMB100A
467Operating Manual 1407.0806.32 ─ 21
Setting parameters:
<State> 0 | 1
Example:
STEReo:DIRect "MASK_STATE=1"
With the command MASK_STATE=1, a sequence of errored
groups as defined by the MASK command is retransmitted once
if the number of groups to be masked is other than zero. Then,
MASK_STATE is automatically set to "0".
If the number of groups to be masked is equal to zero in the
MASK command (which means continuous error transmission),
the masking function can be switched off with MASK_STATE=0.
Example:
STEReo:DIRect? "MASK_STATE"
Response: "1"
The MASK_STATE query provides information as to whether the
RDS data stream is linked to an error mask.
STEReo:DIRect
"MODE=<EMODE>"
STEReo:DIRect? "MODE"
(for documentation reasons only)
Sets one of various transmit modes.
Use the SCPI command [:SOURce]:STEReo:AUDio:MODE instead.
Setting parameters:
<EMODE> 1 | 2 | 3 | 4 | 5
1
L: signal in left channel only
2
R: signal in right channel only
3
signal of equal frequency and phase in left and right channel
4
signal of equal frequency and opposite phase in left and right
channel
5
different, independent signals in left and right channel
(5 is not possible if the internal LF generator is selected as
source (SRC = LFGen))
Example:
STEReo:DIRect "MODE=1"
Only the signal of the left channel is transmitted.
Example:
STEReo:DIRect? "MODE"
Response: "1"
Direct Commands for the Stereo/RDS Coder Option R&S SMB-B5