Main SP Tables-3
D146/D147/D148/D149/D150 2-372 System Maintenance Section
Displays target value of TD sensor's (K) output voltage when executing TD
sensor initial setting.
012
Initial: C *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Displays target value of TD sensor's (C) output voltage when executing TD
sensor initial setting.
013
Initial: M *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Displays target value of TD sensor's (M) output voltage when executing TD
sensor initial setting.
014
Initial: Y *ENG [0.00 to 5.00 / 2.50 / 0.01V/step]
Displays target value of TD sensor's (Y) output voltage when executing TD
sensor initial setting.
3230
[Vtref :Disp/Set]
Displays pixel correction amount of Vtref correction by image area.
021 Pixel Correction: K *ENG
[-5.00 to 5.50 / 0.00 / 0.01V/step]
022 Pixel Correction: C *ENG
023 Pixel Correction: M *ENG
024 Pixel Correction: Y *ENG
3231 [Vtref Limits :Set]
001
Upper:K *ENG [0.00 to 5.00 / 4.00 / 0.01V/step]
Sets upper limit for target value of TD sensor's output voltage: Vtref (K).
002
Upper:C *ENG [0.00 to 5.00 / 4.00 / 0.01V/step]
Sets upper limit for target value of TD sensor's output voltage: Vtref (C).
003
Upper:M *ENG [0.00 to 5.00 / 4.00 / 0.01V/step]
Sets upper limit for target value of TD sensor's output voltage: Vtref (M).
004
Upper:Y *ENG [0.00 to 5.00 / 4.00 / 0.01V/step]
Sets upper limit for target value of TD sensor's output voltage: Vtref (Y).