Service Call 900-998
SM 5-191 D146/D147/D148/D149/D150
5.10.2 SC900 (CONTROLLER)
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC900-00 D
Electric counter error
The electric total counter value is out of specification.
Error is detected when increasing the total counter.
§ Unexpected NV-RAM is attached.
§ NV-RAM defective
§ NV-RAM data corrupted.
§ Data written to unexpected area because of external factor
etc.
§ The count requested by the SRM on receiving PRT is not
completed.
Replace the NV-RAM.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC910-00 B
External Controller Error 1
Notification from external application (external controller)
Subject to external application (external controller) specification
Turn the main power off/on.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC911-00 B
External Controller Error 2
Notification from external application (external controller)
Subject to external application (external controller) specification
Turn the main power off/on.