Main SP Tables-7
System Maintenance Section 2-717 D146/D147/D148/D149/D150
SP Mode Tables
013
Attachment: Total Counter ENG [0 to 99999999 / 0 / 1/step]
Writes main unit total counter value in binary data when toner installed.
014
Refill Information *ENG [0 or 1 / 0 / 1/step]
Refill detect, IS ware detect information.
7937 [Toner Bottle Log 3: C]
021
SerialNo. ENG [0 or 1 / 0 / 1/step]
Display conventional ASCII 16 byte in 8byte BCD.
022
Attachment Date ENG [0 or 1 / 0 / 1/step]
Write year/month/day of toner installed.
023
Attachment: Total Counter ENG [0 to 99999999 / 0 / 1/step]
Writes main unit total counter value in binary data when toner installed.
024
Refill Information *ENG [0 or 1 / 0 / 1/step]
Refill detect, IS ware detect information.
7937 [Toner Bottle Log 4: C]
031
SerialNo. ENG [0 or 1 / 0 / 1/step]
Display conventional ASCII 16 byte in 8byte BCD.
032
Attachment Date ENG [0 or 1 / 0 / 1/step]
Write year/month/day of toner installed.
033
Attachment: Total Counter ENG [0 to 99999999 / 0 / 1/step]
Writes main unit total counter value in binary data when toner installed.
034
Refill Information *ENG [0 or 1 / 0 / 1/step]
Refill detect, IS ware detect information.