Input Check Table
D146/D147/D148/D149/D150 3-12 System Maintenance Section
Detects setting of key counter.
(0: unset, 1:set)
(key counter: set 1=0, 2=1 for set, others for unset)
074
Key Card Set ENG
[0 or 1 / 0 / 1/step]
0: set
1: not set
Detects that key card is set to main unit.
(0: set, 1:not set)
075
1 Bin Tray: Paper Sensor ENG
[0 or 1 / 0 / 1/step]
0: paper exist
1: paper non exist
Detects that paper is left upon the tray.
(0: paper exist, 1: paper non exist)
076
1 Bin Tray: Set Detection
System
ENG
[0 or 1 / 0 / 1/step]
0: paper exist
1: paper non exist
Detects that tray is set to main unit.
(0: set, 1:not set)
077
Bridge Relay Sensor ENG
[0 or 1 / 0 / 1/step]
0: paper exist
1: paper non exist
Responds to paper existence on carry sensor position or bridge unit.
(0: paper exist, 1: paper non exist)
078
Bridge Exit Sensor ENG
[0 or 1 / 0 / 1/step]
0: Paper exist
1: Paper do not exist
Responds to paper existence on paper exit sensor position or bridge unit.
(0: paper exist, 1: paper non exist)