D163 50 SM
Code Meaning Suggested Cause/Action
0-08 The other end sent RTN or
PIN after receiving a page,
because there were too many
errors
Check the line connection.
Replace the FCU.
The other end may have jammed, or run
out of paper or memory space.
Try adjusting the tx level and/or cable
equalizer settings.
The other end may have a defective
modem/FCU; try sending to another
machine.
Check for line problems and noise.
Cross reference
Tx level - NCU Parameter 01 (PSTN)
Cable equalizer - G3 Switch 07 (PSTN)
Dedicated Tx parameters in Service
Program Mode
0-14 Non-standard post message
response code received
Incompatible or defective remote terminal;
try sending to another machine.
Noisy line: resend.
Try adjusting the tx level and/or cable
equalizer settings.
Replace the FCU.
Cross reference
See error code 0-08.
0-15 The other terminal is not
capable of specific functions.
The other terminal is not capable of accepting
the following functions, or the other terminal’s
memory is full.
Confidential rx
Transfer function
SEP/SUB/PWD/SID