SM 151 D163
6 Not used Do not change the settings
7
Select detection of reverse
polarity in ringing
0: Off
1: On
This switch is used to prevent reverse polarity in
ringing on the phone line (applied to PSTN-G3
ringing). Do not change this setting
0: No detection
1: Detection (Japan and Korea only)
G3-2 Switch 04 (SP No. 1-106-005)
No Function Comments
0-3
Training error detection
threshold
0 - F (Hex); 0 - 15 bits
If the number of error bits in the received TCF is
below this threshold, the machine informs the
sender that training has succeeded.