D163 172 SM
680547
Country dial tone permissible drop
time
20 ms -
680548 Country dial wait interval (LOW)
680549 Country dial wait interval (HIGH)
68054A
Time between opening or closing
the DO relay and opening the
OHDI relay
1 ms
See Notes 3, 6 and 8.
SP2-103-012
(parameter 11).
68054B Break time for pulse dialing 1 ms
See Note 3.
SP2-103-013
(parameter 12).
68054C Make time for pulse dialing 1 ms
See Note 3.
SP2-103-014
(parameter 13).
68054D
Time between final OHDI relay
closure and DO relay opening or
closing
1 ms
See Notes 3, 6 and 8.
SP2-103-015
(parameter 14).
This parameter is only
valid in Europe.
68054E
Minimum pause between dialed
digits (pulse dial mode)
20 ms
See Note 3 and 8.
SP2-103-016
(parameter 15).
68054F
Time waited when a pause is
entered at the operation panel
SP2-103-017
(parameter 16). See
Note 3.
680550 DTMF tone on time
1 ms
SP2-103-018
(parameter 17).
680551 DTMF tone off time
SP2-103-019
(parameter 18).