Imageable Area Extension Unit Type M3
D146/D147/D148/D149/D150 2-164 SM
SP Description Default Setting
SP1-117-144
Repeat Temp. Correction
Temp.:End:1:SRA3:M-thick
D150: 5
D149: 5
D148: 5
D147: 25
D146: 25
D150: 20
D149: 20
D148: 20
D147:
25(same
as Int)
D146:
25(same
as Int)
§ When SP2-400-001 is changed over, a message is displayed stating “Switch the
power OFF/ON”.
2. After all SP values are changed, turn the power off.
3. Replace the roller.
[A]: Standard roller
[B]: Imageable Area Extension Unit Type M3
§ During PM replacement, do not install the wrong type of roller.
4. Turn the power on.
5. Using SRA3 paper, check that a full-bleed halftone image is output, and that the image
extends to 315 mm in width.