Image Transfer Unit
SM 4-77 D146/D147/D148/D149/D150
and Adjustment
§ TM/P Sensor (front): F, TM/P Sensor (center): C, TM/P Sensor (rear): R, be careful.
2. Turn on the main power switch, and then go into the SP mode.
3. Input the characteristic values.
Input data for TM/P Sensor: F into SP3-333. Input data for TM/P sensor: C into SP3-334.
Input data for TM/P sensor: R into SP3-335.
SP No. Classification 1 Classification 2 Value
3-333-001 ID.Sens TestVal:F K2: Check TM/P sensor: F, value of [1]
3-333-002 ID.Sens TestVal:F Diffuse Corr TM/P sensor: F, value of [2]
3-333-003 ID.Sens TestVal:F
Vct_reg
Check:Slope
TM/P sensor: F, value of [3]
3-333-004 ID.Sens TestVal:F
Vct_reg
Check:Xint
TM/P sensor: F, value of [4]
3-333-005 ID.Sens TestVal:F
Vct_dif
Check:Slope
TM/P sensor: F, value of [5]
3-333-006 ID.Sens TestVal:F
Vct_dif
Check:Xint
TM/P sensor: F, value of [6]
3-334-001 ID.Sens TestVal:C K2: Check TM/P sensor: C, value of [1]
3-334-002 ID.Sens TestVal:C Diffuse Corr TM/P sensor: C, value of [2]
3-334-003 ID.Sens TestVal:C
Vct_reg
Check:Slope
TM/P sensor: C, value of [3]
3-334-004 ID.Sens TestVal:C
Vct_reg
Check:Xint
TM/P sensor: C, value of [4]
3-334-005 ID.Sens TestVal:C
Vct_dif
Check:Slope
TM/P sensor: C, value of [5]