Service Call 101-195
D146/D147/D148/D149/D150 5-16 SM
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC161-02 D IPU error (Ri response abnormal)
The machine detects an error during an access to the Ri.
IPU (BiCU, iCTL) board defective (Ri response abnormal, etc.)
Replace the IPU (or BiCU) board.
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC165-00 D Copy data security unit error
§ The copy data security option is enabled in the User Tools
but the option board is detected as missing or defective.
§ The copy data security option was detected as defective
when the machine was turned on or returned from energy
save mode.
§ Copy data security unit board not installed correctly
§ Copy data security unit board defective
§ Reinstall the copy data security unit board.
§ Replace the copy data security unit board.