Service Call 201-285
SM 5-25 D146/D147/D148/D149/D150
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC230-01 D FGATE ON error: Bk
SC230-02 D FGATE ON error: Cy
SC230-03 D FGATE ON error: Ma
SC230-04 D FGATE ON error: Ye
The FGATE signal did not turn ON within T1 sec. after the
writing process of the corresponding color started.
§ GAVD defective
§ Image processing ASIC defective
§ BCU, controller board not connected correctly or defective
§ Harness between IPU and LDB defective
§ Turn the power off/on
§ Replace the IPU board
§ Replace the controller board
SC No. Level Error Name/Error Condition/Major Cause/Solution
SC231-01 D FGATE OFF error: Bk
SC231-02 D FGATE OFF error: Cy
SC231-03 D FGATE OFF error: Ma
SC231-04 D FGATE OFF error: Ye
§ The FGATE signal did not turn OFF within T1 sec. after the
writing process of the corresponding color ended.
§ The FGATE signal did not turn OFF when the next job of the
corresponding color started.
§ GAVD defective
§ Image processing ASIC defective
§ Turn the power off/on.
§ Replace the IPU board.
§ Replace the controller board.